Extruded Aluminum Indoor Architectural LED Exit Sign Product Series Code: AAX


MSRP: $170.00
Your Starting Price: $130.00
Savings: $40.00 (23.53%)

Shipping Weight:8.00 .lbs

Quantity in Basket: None

Volume Price

10-30 31-50 51+
$126.10 $122.20 $117.00
Discounts Applied at Checkout


As Configured:

check out
  • Send this item to a friend

Product Characteristics


PRODUCT OVERVIEW: The Greentorch AAX Series Commercial Extruded Aluminum Indoor Exit Sign features an attractive and slim housing design. Ideal for commercial and institutional installations, the slim profile of this extruded fixture blends perfectly with current interior decors. The AAX Series is configured with high-output, red or green LEDs. The AAX is available in AC only and battery backup versions.

CONSTRUCTION: The clean lines and thin design of the AAX Series Exit Sign provides a modern and attractive appearance. The extruded aluminum frame contains no external holes or slots adding to the clean look while eliminating unwanted light leaks. The aluminum also forms a rigid and durable frame that can be securely mounted in any application. The face and back plates are mounted into the frame using a pin and channel system that permits simple and speedy removal during installation. This design also eliminates the need for any visible screws or fasteners.

ILLUMINATION: The AAX Series is configured with high-output, red or green LED lamps. The AAX Series is standard with 120/277VAC input. All versions consume 2-4 watts of electricity for red or green LEDs, respectively.

EXIT FACE:
Letter Size: 6” letters with ¾” stroke

Directional Indicators: Infield applicable chevron arrows sized to meet UL visibility requirements.

BATTERY TECHNOLOGY: AAX Series models with the battery backup option are designed with a maintenance free, sealed Nickel-Cadmium battery that provides a minimum 90 minutes of emergency operation. Recharge time of the battery is 24 hours. The maximum battery working temperature is 50 C or 122 F.

INSTALLATION: AAX Series exit signs are suitable for surface ceiling , wall and end mounting. They are suitable for indoor and damp location installations on normally inflammable surfaces. The AAX comes with all necessary installation hardware.

ELECTRICAL SPECIFICATIONS:
Utility Input: 120/277VAC, 60Hz

Temperature Range: Maximum battery working temperature is 50 C or 122 F

Recharge Duty Cycle: 24 hours

Controls: External test switch and monitor LED are standard on BB versions

Low Voltage Battery Disconnect: Sealed nickel-cadmium batteries provide a minimum 90 minutes of emergency operation; electronic cut-off circuit prevents over discharge.

CODE COMPLIANCE: All models are UL924, CSA, ETL, NFPA101 Life Safety, state and local codes.


Question : How do I configure the arrows for my sign?
Answer : Many signs come with the ability to set the arrows to your preference at the time of installation. This is called 'infield' applicable arrows. Almost all signs come with field applicable arrows. Here is how they differ. thermoplastic signs have pop-out arrows that can be removed or added to your choice. Cast-Aluminum signs have knock-outs. knock-outs are where we indent the back side of the face plate with a cut in the shape of arrows requiring the tap of a screw driver or hammer to 'knock' them all the way out. It is difficult to add back knocked-out arrows because the seams are exposed. It can be done, but it looks nicer when you are accurate. Self-luminous and photoluminescent signs use stencils and/or adhesive arrows. The adhesive arrows can only be applied once. You can remove them after application but the y are designed for permanent adhesion. The stencils can be popped out. Edge-lit exit signs can have the arrows pre-specified, adhesive, or static. Our signs use either static or pre-configured in general, as the panels for edge-lits are prone to smudges and fingerprints. Our signs look great because our chevrons are designed for easy and clean installation, minus the smudges.
Question : Does this exit sign plug-in to a wall outlet?
Answer : No. LED and other types of electrical exit signs have to be hard-wired into your electrical system. Electrical exit signs must be hard-wired to be building and fire code compliant. If you are looking for an exit sign to use in a location that does not have electricity available please look at our non-electrical Self Luminous and Photoluminescent exit signs.
Question : How do I know if this exit sign is approved for use in my city/county/state?
Answer : The UL listing (Underwriters Laboratories) for of our exit signs ensures that these signs are code compliant. UL tests our exit signs and then gives their approval. This approval comes in the form of a listing. As long as your exit sign is UL listed it will work for your jurisdiction. Two exceptions exist: New York City and Chicago, which have their own exit sign specifications in addition to the UL listing.
Question : Does it matter if I choose red or green letters for my exit sign?
Answer : It only matters that you be consistent. If you have green exit signs now, purchase more green; if you have red, purchase more red. What you want to avoid is a mismatching of exit sign colors. Pick one color and stick with it. Recent studies have suggested that green exit signs are better choices because the green color makes people think, “go” whereas red makes people think, “stop”. Always check with you building/fire inspector for local/regional codes that might require red or green letters specifically. This does no apply to New York City and Chicago, as they have their own specific specifications for exit signs.
Question : What does 120/277v mean?
Answer : 120/277 refers to the line voltage that the exit sign can operate on. 120 refers to residential and small commercial line voltage while 220 refers to commercial and office building line voltage. The main point is that our exit signs will work in either situation so you don’t need to worry about the functionality. We recommend using a licensed electrician or maintenance professional to install exit signs, emergency lights and other safety egress equipment.
Question : What is and do I need the battery backup option?
Answer : The battery backup option provides emergency battery power to illuminate your exit sign or emergency light in case of a fire, earthquake, or other emergency that causes a power outage. You must have the battery backup model if you DO NOT have a generator that provides emergency power to your facility.
Our products typically carry a 5 year warranty though on certain items the warranty is longer. All products are guaranteed to be new, and free from defect. Batteries carry a 5 year prorated warranty. For specific warranty related questions, contact us and we will provide you with any needed information.

name AAX Extruded Aluminum Indoor Architectural Exit Sign

Body Height 7.5

Body Width 13

Body Depth 2

Sign Face Count Single Sided,Double Sided

Listings UL924 US,ETL

Damp Location Rated No

Light Source LED

Body Material Cast Aluminum

Canopy Material Aluminum

Back Up Power AC Only,AC Dual Circuit,Battery Backup

Country Of Origination Canada

Mounting Install Type Flush ,Universal Canopy,Top,Side

ArrowsChevrons Infield Applicable

Includes Battery Yes

Battery Terminal Type NA

Battery Model

Face Color White,Black,Brushed Aluminum

Frame Color NA

Letter Color Red,Green

Letter Height 6

Letter Stroke .75

Canopy Width 0

Canopy Height 0

Canopy Depth 0

Viewing Distance 100

Wet Location Rated No

Pendant Kit Capable Yes

AC Current Hz 60

Voltage 120,277

Remote Capable? No

Exit Sign Unit Wattage 1.1

Self Diagnostic Testing Yes

Compliance UL924,EnergyStar,NFPA101 Life Safety,CSA

IP65 Rated No

Emergency Light Capable? No

Class 1 Div 2 No

Frame's Sign Face Count 2

Emergency Light Bulb Type NA

Battery Amperes Hours .7

Battery Type Nickel Cadmium

Thumbnail Picture Link

Battery Volts 6,12,24

Max Operation Temperature 122

Max Operation Temperature Celsius 50

Regional Approvals Canada

name AAX Extruded Aluminum Indoor Architectural Exit Sign