PRODUCT OVERVIEW: The EXT series of industrial emergency lighting units are designed to be affordable, durable and dependable. The NEMA 4x rated fiberglass housing can be used in most damp, wet and hose down areas. The EXT series has been designed with a pulse switching charger. The pulse switching charger offers superior performance & energy efficiency versus conventional constant voltage chargers. Traditional top mounted Par36 style heads are standard.

CONSTRUCTION: The EXT series is constructed with a durable NEMA 4x rated fiberglass cabinet. Industrial gray finish is standard. Emergency lighting heads are molded from 2 high impact thermoplastic, two top mounted Par36 style 9w heads. Lamp head styles are constructed of high impact thermoplastic. Please note: Par36 style food-prep approved lenses are also available when ordering. Integrated mounting feet ensure proper and secure installation. External test switch and monitor LED are standard.

ILLUMINATION: Available with 2, top mounted Par36 style lamp heads. 6V TUNGSTEN: standard: 9w, (H) halogen: 8w, 10w, 12w, 20w 6V SEALED BEAM: (SB) standard: 9w, 12w, 18w (SBH) halogen: 12w, 20w 12V TUNGSTEN: standard: 9w, 18w (H) halogen: 8w, 12w, 20w, *35w, *55w (*LR only) 12V SEALED BEAM: (SB) standard: 12w, 18w (SBH) halogen: 8w


BATTERY TECHNOLOGY: The EXT series is designed with maintenance free, sealed valve regulated lead acid battery that provides a minimum emergency duration of 90 minutes (for the listed rating). Recharge time of the battery is twenty-four (24) hours. The maximum working temperature is 50 C.

INSTALLATION: The EXT is suitable for surface wall mounting. Suitable for NEMA 4x required installations. The front access panel is hinged for trouble-free installation and maintenance. Four integrated mounting feet ensure proper, secure and accurate wall or ceiling installation on to most surfaces.

ELECTRICAL SPECIFICATIONS: Charger Type: fully automatic current limited charger with solid state linelatched low voltage disconnect protection
Utility Input: 120/277VAC, 60 Hz.
Temperature Range: Max 50 C
Recharge Duty Cycle: 24 hours
Load Transfer: A solid state transfer circuit provides load connection.
Controls: Momentary tETS switch and LED AC-On indicator light
Safety Circuitry: AC Lockout: Prevents battery discharge prior to initial unit power-up saving installation time.
Low Voltage Battery Disconnect: Protects the battery from being severely damaged by deep discharge during prolonged power failures. Brownout Protection: Automatically switches the unit to emergency mode when utility voltage is reduced to the point at which most fluorescent light fixtures would extinguish.

CODE COMPLIANCE: ETL listed to UL924 standards.


Question : What is and do I need the battery backup option for my emergency light?
Answer : The battery backup option provides power to your emergency lights in case of a fire, earthquake, or other emergency that causes a power outage. You must have the battery backup model if you DO NOT have a generator that provides power to your facility in emergency circumstances.
Question : When do emergency lights come on?
Answer : Emergency lights turn on when power is lost to the facility. When equipped with a battery backup or supplied with electricity from a generator, Greentorch emergency lights will operate for a minimum of 90 minutes in emergency situations.
Question : Does this emergency light plug-in to a wall outlet?
Answer : No. Emergency lights have to be hard-wired into your electrical system to be building and fire code compliant. If you are looking for a 100% battery operated emergency light it does not exist because it is impossible to charge the battery for the light without a source of electricity. Batteries in emergency lights have a trickle charge, which means the battery uses a minute amount of electricity to stay charged incase of an emergency power outage.
Question : What does 120/277v mean?
Answer : 120/277 refers to the line voltage that the emergency light can operate on. 120 refers to residential and small commercial line voltage while 220 refers to commercial and office building line voltage. The main point is that our emergency lights will work in either situation so you don’t need to worry about the functionality. We recommend using a licensed electrician or maintenance professional to install the signs.
Question : Are there emergency lights with batteries that operate longer than 90 minutes in emergency power mode?
Answer : Yes, there are. The higher the wattage of the emergency lighting unit the longer the unit will operate in emergency power mode (while keeping the lamp head wattage constant). Please see our industrial line of emergency lights, which come with large batteries (up to 400 watts).
Question : What is remote head capability?
Answer : Remote head capability means that the emergency lighting unit has been equipped with a battery that is powerful enough to supply power remotely to individual lamp heads. The larger the battery, the more remote heads a unit can handle.
Our products typically carry a 5 year warranty though on certain items the warranty is longer. All products are guaranteed to be new, and free from defect. Batteries carry a 5 year prorated warranty. For specific warranty related questions, contact us and we will provide you with any needed information.

Name EXT NEMA 4X Industrial Emergency Light

Body Height 12

Body Height 14

Body Height 16

Body Height 8

Body Width 10

Body Width 12

Body Width 14

Body Width 6

Body Depth 4

Body Depth 5

Body Depth 6

Listings UL924 US,ETL

Damp Location Rated Yes

Light Source Halogen

Light Source Tungsten

Body Material Fiberglass

Back Up Power AC Only,Battery Backup

Country Of Origination NA

Mounting Install Type Flush ,Top

Includes Battery Yes

Battery Terminal Type F1

Wet Location Rated Yes

Pendant Kit Capable Yes

AC Current Hz 60

Voltage 120,277

Remote Capable? No

Compliance UL924,CSA

IP65 Rated Yes

Battery Amperes Hours 0

Battery Type Nickel Cadmium,Sealed Lead Acid

Item Options Time Delay,Auto Test,Internal Heater,Food Prep Lenses,Shatter-proof Heads

Unit Wattage 27,36,54,72,100,200,300,400

Emergency Head Wattage Options 8,9,10,12,18,20

Standard Lamp Count 1,2

Battery Volts 6,12

Max Operation Temperature 122

Min Operation Temperature 0

Max Operation Temperature Celsius 50

Min Operation Temperature Celsius 0

Regional Approvals Canada

Name EXT NEMA 4X Industrial Emergency Light

Thumbnail Picture Link dimensionstnEXT-d.png

High Res