greentorch

Need help? 888 394 8786

Class 1 & 2 Division 2 LED Combo Direct View Exit Sign with Emergency Lights Product Series Code: H-WL


MSRP: $1400.00
Your Starting Price: $880.00
Savings: $520.00 (37.14%)

Shipping Weight:20.00 .lbs

Quantity in Basket: None

Volume Price

10-30 31-50 51+
$866.80 $853.60 $836.00
Discounts Applied at Checkout


As Configured:

check out
  • Send this item to a friend

Product Characteristics


PRODUCT OVERVIEW: The H-WL Series LED Exit combines energy-saving LED technology with the added safety of an exit sign and emergency lighting. The H-WL’s rugged construction is ideal for use in NEC Class I & II areas. The H-WL exit sign features corrosion-resistant, gasketed enclosures and high output, wet location rating, and optional self-diagnostics.

CONSTRUCTION: Impact resistant, industrial gray fiberglass reinforced polyester enclosure with stainless steel hardware is completely sealed and gasketed. The enclosure includes a clear polycarbonate cover. The lighting heads are constructed from impact resistant, UV stable, flame rated thermoplastic lamp housing and swivel assemblies in gray finish to match unit housing. Heads and swivels are sealed and gasketed. Lighting heads are fully adjustable and feature lockable swivels.

ILLUMINATION: Exit face illumination is provided by a special high intensity direct-view red or green LED panel. Letter brightness and illumination uniformity exceed UL requirements. LED lamp life rated for an average 25 years.

EXIT FACE:
Letter Size: 6” letters with 3/4” stroke
Directional Indicators: Infield applicable chevron arrows sized to meet UL visibility requirements.

BATTERY TECHNOLOGY: Sealed Lead Calcium maintenance free battery designed to provide many years of dependable service.

INSTALLATION: Units are designed for installation to wall surfaces by means of internal knockouts or four external mounting feet provided with the enclosure. Wiring: A wiring hub is provided on the right hand side of the enclosure for attachment of surface wiring conduit.

ELECTRICAL SPECIFICATIONS: Charger Type: Emergency exit models utilize a fully automatic, temperature compensating, constant current type charger. All combination unit models utilize a fully automatic, temperature compensating, variable rate type charger.
Utility Input: 120/277VAC, 60 Hz.
Temperature Range: 32ºF to 104ºF or 0ºC to 40ºC
Recharge Duty Cycle: 24 hours
Load Transfer: Solid state transfer circuit
Controls: Momentary test switch and LED AC-On indicator light
Safety Circuitry: AC Lockout: Prevents battery discharge prior to initial unit power-up saving installation time.
Low Voltage Battery Disconnect: Protects the battery from being severely damaged by deep discharge during prolonged power failures. Short Circuit Protection: On units with solid state transfer, output protection is provided by a disconnect circuit that automatically resets itself when the fault condition is corrected. Brownout Protection: Automatically switches the unit to emergency mode when AC voltage sags below 80% of nominal.

CODE COMPLIANCE: All models meet NFPA 101 Life Safety Code, NEC, OSHA, BOCA, state and local codes. Emergency models are UL924, 844 and 1604 Listed.


Question : How do I configure the arrows for my sign?
Answer : Many signs come with the ability to set the arrows to your preference at the time of installation. This is called 'infield' applicable arrows. Almost all signs come with field applicable arrows. Here is how they differ. thermoplastic signs have pop-out arrows that can be removed or added to your choice. Cast-Aluminum signs have knock-outs. knock-outs are where we indent the back side of the face plate with a cut in the shape of arrows requiring the tap of a screw driver or hammer to 'knock' them all the way out. It is difficult to add back knocked-out arrows because the seams are exposed. It can be done, but it looks nicer when you are accurate. Self-luminous and photoluminescent signs use stencils and/or adhesive arrows. The adhesive arrows can only be applied once. You can remove them after application but the y are designed for permanent adhesion. The stencils can be popped out. Edge-lit exit signs can have the arrows pre-specified, adhesive, or static. Our signs use either static or pre-configured in general, as the panels for edge-lits are prone to smudges and fingerprints. Our signs look great because our chevrons are designed for easy and clean installation, minus the smudges.
Question : Does this exit sign plug-in to a wall outlet?
Answer : No. LED and other types of electrical exit signs have to be hard-wired into your electrical system. Electrical exit signs must be hard-wired to be building and fire code compliant. If you are looking for an exit sign to use in a location that does not have electricity available please look at our non-electrical Self Luminous and Photoluminescent exit signs.
Question : How do I know if this exit sign is approved for use in my city/county/state?
Answer : The UL listing (Underwriters Laboratories) for of our exit signs ensures that these signs are code compliant. UL tests our exit signs and then gives their approval. This approval comes in the form of a listing. As long as your exit sign is UL listed it will work for your jurisdiction. Two exceptions exist: New York City and Chicago, which have their own exit sign specifications in addition to the UL listing.
Question : What is and do I need the battery backup option?
Answer : The battery backup option provides emergency battery power to illuminate your exit sign or emergency light in case of a fire, earthquake, or other emergency that causes a power outage. You must have the battery backup model if you DO NOT have a generator that provides emergency power to your facility.
Question : I’ve seen similar looking exit signs for cheaper prices on other websites, why should I buy yours?
Answer : Simply put, we are the BEST. No one knows safety egress products like we do and no one stands behind and guarantees their products like we do. We offer more choices and higher quality products than our competitors. We have and continue to work with some of the largest and most exclusive companies in the world including McDonald’s, US Army, United Nations, and Giorgio Armani. If you are looking for the cheapest exit sign on the internet you are not going to find it here. If you are looking for a reliable, high-quality exit sign or emergency light from a company that can deliver on time and has the expertise to solve any type of obstacle or problem that could occur, you have come to the right place. The top quality appearance of our Greentorch website is matched by the effort and expertise of our knowledgeable and qualified team of sales technicians who are available through our toll free number (877-305-0898).
Our products typically carry a 5 year warranty though on certain items the warranty is longer. All products are guaranteed to be new, and free from defect. Batteries carry a 5 year prorated warranty. For specific warranty related questions, contact us and we will provide you with any needed information.

Name H-WL Class 1&2 Div 2 LED EmergencyExit Combo

Body Height 11.2

Body Height 17.5

Body Width 13.2

Body Depth 6.6

Sign Face Count Single Sided

Listings UL924 US

Damp Location Rated No

Light Source LED

Body Material Steel,PolyCarbonate

Canopy Material

Back Up Power AC Only,Battery Backup

Country Of Origination NA

Mounting Install Type Flush ,Bottom

ArrowsChevrons Infield Applicable

Includes Battery Yes

Battery Terminal Type NA

Battery Model

Face Color Gray

Frame Color Gray

Letter Color Red,Green

Letter Height 6

Letter Stroke .75

Canopy Width 0

Canopy Height 0

Canopy Depth 0

Viewing Distance 100

Wet Location Rated Yes

Pendant Kit Capable No

AC Current Hz 60

Voltage 120,277

Remote Capable? No

Self Diagnostic Testing Yes

Compliance UL924,EnergyStar,NFPA101 Life Safety,OSHA

IP65 Rated No

Emergency Light Capable? Yes

Class 1 Div 2 Yes

Frame's Sign Face Count 1

Emergency Light Bulb Type Halogen

Battery Amperes Hours 0

Acrylic Panel Options NA

Battery Type Sealed Lead Calcium

Item Options Auto Test,Shatter-proof Heads,Special Transformer

Unit Wattage 12,60,6,24

Emergency Head Wattage Options 6

Standard Lamp Count 1,2,0

Hazardous Rating Class I,II

Hazardous Rating Division 2

Hazardous Rating Groups A,IIA,B,IIB,C,11C,D,F,G,H

Hazardous Rating Zones 2

Battery Volts 6

Max Operation Temperature 85

Min Operation Temperature 65

Max Operation Temperature Celsius 30

Min Operation Temperature Celsius 19

Name H-WL Class 1&2 Div 2 LED EmergencyExit Combo

Thumbnail Picture Link dimensionstnH-WL-d.jpg

High Res