Product Characteristics


PRODUCT OVERVIEW: The LPEM Series Recessed Emergency Light is a high-capacity recessed lighting unit with a high-end aesthetic appeal. The LPEM features an ultra low profile design and maintenance free Sealed Lead Acid or Nickel Cadmium battery options. The LPEM is made from 20-gauge steel and ABS Thermoplastic. Installs into both suspended ceilings and drywall surfaces. The LPEM is available in a white or black finish with multiple lamp head options.

CONSTRUCTION: Backbox constructed of 20 gauge galvanized steel with 1/2” conduit knockouts. Faceplate constructed of impact resistant, UL 94 V-0, 5 VA white thermoplastic. (6 volt units only) 12 Volt units utilize a 12 gauge steel trim plate with a durable powder-coat finish in white or black.

ILLUMINATION: Illumination is provided by two adjustable lamp heads. Choose from round or rectangular thermoplastic heads with Par 36 sealed beam tungsten or halogen, or wedge base tungsten or halogen lamps.


BATTERY TECHNOLOGY: Choice of maintenance-free, sealed lead calcium or maintenance-free, sealed nickel cadmium batteries. Maintenance-free, sealed lead calcium battery has an estimated service life of 5 years, and an operating temperature range of 65°F (19°C) to 85°F (30°C). Maintenance-free, sealed nickel cadmium battery has an estimated service life of 10 years, and an operating temperature range of 20°F (-7°C) to 95°F (35°C). Nickel cadmium batteries are ideal for high ambient temperature areas. Batteries supply 90 minutes of emergency power.

INSTALLATION: Fully recessed assembly for ceiling or wall installation. An optional bar hanger kit is available for mounting in suspended ceilings.

ELECTRICAL SPECIFICATIONS:
Utility Input: 120/277VAC, 60 Hz.
Temperature Range: With sealed lead calcium battery temp. range of 65°F (19°C) to 85°F (30°C); with sealed nickel cadmium battery temp range of 20°F (-7°C) to 95°F (35°C).
Recharge Duty Cycle: 24 hours
Load Transfer: All models utilize mechanical relays for load transfer and provide fused DC load connections.
Controls: Momentary test switch and LED AC-On indicator light
Safety Circuitry: AC Lockout: Prevents battery discharge prior to initial unit power-up saving installation time.
Low Voltage Battery Disconnect: Protects the battery from being severely damaged by deep discharge during prolonged power failures. DC Overload and Short Circuit Protection: Provided by fused output connections. Brownout Protection: Automatically switches the unit to emergency mode when utility voltage is reduced to the point at which most fluorescent light fixtures would extinguish.

CODE COMPLIANCE: UL 924 listed NFPA 101, NEC, BOCA, OSHA and IBC illumination standards, complies with state and local codes.


Our products typically carry a 5 year warranty though on certain items the warranty is longer. All products are guaranteed to be new, and free from defect. Batteries carry a 5 year prorated warranty. For specific warranty related questions, contact us and we will provide you with any needed information.

name LPEM 20 gauge galvanized steel

Body Height 11.6

Body Width 9.5

Body Depth 5.8

Listings UL924 US

Damp Location Rated Yes

Light Source Halogen

Light Source Tungsten

Body Material Steel

Back Up Power AC Only,Battery Backup

Country Of Origination NA

Mounting Install Type Flush ,Bar Hangers Only,Wall Recessed Cutout

Includes Battery Yes

Battery Terminal Type F1

Wet Location Rated No

Pendant Kit Capable No

AC Current Hz 60

Voltage 120,277

Remote Capable? NA

Compliance UL924,NFPA101 Life Safety,OSHA,IBC,BOCA,NEC

IP65 Rated No

Battery Amperes Hours 0

Battery Type Nickel Cadmium,Sealed Lead Calcium

Item Options Voltmeter

Unit Wattage 18,25,50,75,28

Emergency Head Wattage Options 5.4,7.2,8,9,12,18,25,30

Standard Lamp Count 1,2

Max Operation Temperature 85

Max Operation Temperature 95

Min Operation Temperature 20

Min Operation Temperature 65

Max Operation Temperature Celsius 30

Max Operation Temperature Celsius 35

Min Operation Temperature Celsius 19

Min Operation Temperature Celsius -7

name LPEM Low Profile, Recessed Emergency Light

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 5.4

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 9

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 7.2

Light Source Incandescent

Voltage 12

Emergency Head Wattage Options 12.5

Light Source Incandescent

Voltage 12

Emergency Head Wattage Options 17.9

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 8

Light Source Incandescent

Voltage 12

Emergency Head Wattage Options 12

Light Source Incandescent

Voltage 12.8

Emergency Head Wattage Options 25

Light Source Incandescent

Voltage 12

Emergency Head Wattage Options 30

Light Source Halogen

Voltage 6

Emergency Head Wattage Options 8

Light Source Halogen

Voltage 6

Emergency Head Wattage Options 12

Light Source Incandescent

Voltage 12

Emergency Head Wattage Options 18

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 9

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 7.2

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 10

Light Source Halogen

Voltage 6

Emergency Head Wattage Options 7

Light Source Halogen

Light Source Incandescent

Voltage 6

Emergency Head Wattage Options 12

Light Source Halogen

Light Source Incandescent

Voltage 12

Emergency Head Wattage Options 12

Thumbnail Picture Link dimensionstnLPEM-d.png

High Res