"NEMA 3, 3R, 4, 4X, 6, 12, & 13 LED Combo Exit Sign with Emergency Lights" Product Series Code: RC


MSRP: $900.00
Your Starting Price: $787.06
Savings: $112.94 (12.55%)

Shipping Weight:12.00 .lbs

Quantity in Basket: None

Volume Price

10-30 31-50 51+
$775.25 $763.45 $747.71
Discounts Applied at Checkout


As Configured:

check out
  • Send this item to a friend

Product Characteristics


PRODUCT OVERVIEW: The RC NEMA Series Exit provides excellent emergency signage and lighting while withstanding industrial and wet environments. The RC NEMA Series Exit should be used when durability and harsh environments are a concern. Available in back mount only.

CONSTRUCTION: The RC watertight enclosure is constructed of fiberglass reinforced polyester with a polycarbonate lens cover that provides excellent resistance to impact. The RC NEMA Series Exit housing is rated for NEMA 3, 3r, 4, 4x, 12 and 13 environments. The two head combination emergency/exit features fully adjustable 6 volt, 6 watt Par 36 halogen sealed beam lamp heads that are enclosed in watertight polycarbonate housings.

ILLUMINATION: Illumination of the RC NEMA Series Exit is accomplished with the use of direct view LEDs to provide illumination in excess of UL 924 requirements that enhance visibility and which improve the safety benefits in industrial environments. LEDs offer low maintenance replacement costs and long life. AC only operation uses 6 watts LED power. Emergency mode operation uses 10 watts LED power.

EXIT FACE:
Letter Size: 6” letters with 3/4” stroke
Directional Indicators: Infield applicable chevron arrows sized to meet UL visibility requirements.

BATTERY TECHNOLOGY: The RC Exit uses a maintenance free, nickel cadmium battery with an estimated service life of 10 years, and operating within temperatures of 20°F to 95°F or -7°C to 35°C. The two head combination emergency/exit model uses a maintenance free, sealed lead calcium battery with an estimated service life of 5 years, and operating within temperatures of 65°F to 85°F or 19°C to 30°C.

INSTALLATION: RC available in back mount only. Must comply with the NEC as well as other applicable codes.

ELECTRICAL SPECIFICATIONS:
Load Transfer: Solid-state charging circuitry provides for a reliable charging system
Utility Input: 120/277VAC Dual voltage 60 hertz, unswitched power source Temperature Ranges: With nickel cadmium battery: 20°F to 95°F or -7°C to 35°C; With sealed lead calcium battery: 65°F to 85°F or 19°C to 30°C. Emergency operation: Minimum 90 minutes continuous illumination Brownout Protection: Upon utility power failure or brownout, the unit shall automatically transfer to battery power and maintain the required illumination level for a minimum period of 90 minutes.
Low Voltage Battery Disconnect: Protects the battery from being severely damaged by deep discharge during prolonged power failures
Controls: AC indicator LED and test switch

CODE COMPLIANCE: UL 924 listed NFPA 70 and 101, NEC, BOCA, OSHA and IBC illumination standards, NSF standard Class 2 “Splash Zone” listed Optional damp location listing; optional wet location listing


Question : How do I configure the arrows for my sign?
Answer : Many signs come with the ability to set the arrows to your preference at the time of installation. This is called 'infield' applicable arrows. Almost all signs come with field applicable arrows. Here is how they differ. thermoplastic signs have pop-out arrows that can be removed or added to your choice. Cast-Aluminum signs have knock-outs. knock-outs are where we indent the back side of the face plate with a cut in the shape of arrows requiring the tap of a screw driver or hammer to 'knock' them all the way out. It is difficult to add back knocked-out arrows because the seams are exposed. It can be done, but it looks nicer when you are accurate. Self-luminous and photoluminescent signs use stencils and/or adhesive arrows. The adhesive arrows can only be applied once. You can remove them after application but the y are designed for permanent adhesion. The stencils can be popped out. Edge-lit exit signs can have the arrows pre-specified, adhesive, or static. Our signs use either static or pre-configured in general, as the panels for edge-lits are prone to smudges and fingerprints. Our signs look great because our chevrons are designed for easy and clean installation, minus the smudges.
Question : How do I know if this exit sign is approved for use in my city/county/state?
Answer : The UL listing (Underwriters Laboratories) for of our exit signs ensures that these signs are code compliant. UL tests our exit signs and then gives their approval. This approval comes in the form of a listing. As long as your exit sign is UL listed it will work for your jurisdiction. Two exceptions exist: New York City and Chicago, which have their own exit sign specifications in addition to the UL listing.
Question : What does 120/277v mean?
Answer : 120/277 refers to the line voltage that the exit sign can operate on. 120 refers to residential and small commercial line voltage while 220 refers to commercial and office building line voltage. The main point is that our exit signs will work in either situation so you don’t need to worry about the functionality. We recommend using a licensed electrician or maintenance professional to install exit signs, emergency lights and other safety egress equipment.
Question : What is and do I need the battery backup option?
Answer : The battery backup option provides emergency battery power to illuminate your exit sign or emergency light in case of a fire, earthquake, or other emergency that causes a power outage. You must have the battery backup model if you DO NOT have a generator that provides emergency power to your facility.
Question : I’ve seen similar looking exit signs for cheaper prices on other websites, why should I buy yours?
Answer : Simply put, we are the BEST. No one knows safety egress products like we do and no one stands behind and guarantees their products like we do. We offer more choices and higher quality products than our competitors. We have and continue to work with some of the largest and most exclusive companies in the world including McDonald’s, US Army, United Nations, and Giorgio Armani. If you are looking for the cheapest exit sign on the internet you are not going to find it here. If you are looking for a reliable, high-quality exit sign or emergency light from a company that can deliver on time and has the expertise to solve any type of obstacle or problem that could occur, you have come to the right place. The top quality appearance of our Greentorch website is matched by the effort and expertise of our knowledgeable and qualified team of sales technicians who are available through our toll free number (877-305-0898).
Question : When do emergency lights turn on?
Answer : Emergency lights turn on when power is lost to the facility. When equipped with a battery backup or supplied with electricity from a generator, Greentorch emergency lights will operate for a minimum of 90 minutes in emergency situations.
Our products typically carry a 5 year warranty though on certain items the warranty is longer. All products are guaranteed to be new, and free from defect. Batteries carry a 5 year prorated warranty. For specific warranty related questions, contact us and we will provide you with any needed information.

Name NEMA Rated LED ExitEmergency Combo

Body Height 13.5

Body Height 7.2

Body Height 9.3

Body Width 11.8

Body Depth 7

Sign Face Count Single Sided,Double Sided

Listings UL924 US

Damp Location Rated Yes

Light Source LED

Body Material PolyCarbonate,Fiberglass

Canopy Material

Back Up Power AC Only,Battery Backup

Country Of Origination NA

Mounting Install Type Top,Side

ArrowsChevrons Infield Applicable

Includes Battery Yes

Battery Terminal Type NA

Battery Model

Face Color White

Frame Color NA

Letter Color Red,Green

Letter Height 6

Letter Stroke .75

Canopy Width 0

Canopy Height 2.1

Canopy Depth 0

Viewing Distance 100

Wet Location Rated Yes

Pendant Kit Capable No

AC Current Hz 60

Voltage 120,277

Remote Capable? No

Exit Sign Unit Wattage 6

Self Diagnostic Testing No

Compliance UL924,EnergyStar,NFPA101 Life Safety,OSHA,IBC,BOCA,NFPA 70

IP65 Rated Yes

Emergency Light Capable? Yes

Class 1 Div 2 No

Frame's Sign Face Count 2

Emergency Light Bulb Type Halogen

Battery Amperes Hours 0

Acrylic Panel Options NA

Battery Type Nickel Cadmium,Sealed Lead Acid

Item Options Tamper-proof Screws,Shatter-proof Heads,Special Transformer,Flasher,Mounting Feet

Unit Wattage 12

Emergency Head Wattage Options 6

Standard Lamp Count 2

Battery Volts

Max Operation Temperature 85

Max Operation Temperature 95

Min Operation Temperature 20

Min Operation Temperature 65

Max Operation Temperature Celsius 30

Max Operation Temperature Celsius 35

Min Operation Temperature Celsius 19

Min Operation Temperature Celsius -7

Name RC NEMA Rated LED ExitEmergency Combo

Thumbnail Picture Link dimensionstnRC-d.png

High Res